Fetch Pipe, Tube and Hose Data

Connection lines can be assigned to the Tube, Pipe and Hose data from the library, based on the design requirements.

Specify Connector type for the connection line to select the default connection properties from the library.

1.     Select the connection line.

2.     Select the connector type from the drop-down list.

3.     Specify the design requirements, pressure and flow for the selected connection lines in the HyDraw® Property Manager.

4.     Click the Select from Library icon.

The Fetch Pipe/Tube/Hose from Library dialog box displays.

5.     Select either Pressure line or Return line.

6.     Select Type, i.e. Pipe/Tube/Hose.

7.     Select Material.

Pressure and flow are automatically displayed in the Design requirements section.
Velocity is displayed per the recommended velocity set in the HyDraw Options dialog box.

The inner diameter is based on the flow and velocity, and the appropriate pipe/tube/hose is selected by default in the grid displaying all the other available pipes/tubes/hoses with velocity.

8.     Select the required pipe, tube or hose.

9.     Click OK and exit.

 

Note: